Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
Int. j. odontostomatol. (Print) ; 12(4): 368-375, dic. 2018. graf
Article in English | LILACS | ID: biblio-975759

ABSTRACT

ABSTRACT: The aim of this study was to carry out a literature review on the accuracy of conventional and digital dental impression methods, as well as present the various three-dimensional intraoral scanning systems. A bibliographic search was carried out in PUBMED's main health database, in which works published between 2008 and 2018 were collected. Laboratory studies, case reports and systematic reviews were included, addressing topics that deal with conventional digital materials, impression and precision. Articles that did not evaluate impression materials, their behavior and techniques to obtain a good impression of oral structures were excluded. Through a review in the literature, obtained the following findings: the most critical stage in macking a dental prothesis is to take the dental impression. The conventional technique of impression consists of obtaining a negative copy of the intra-oral situation that will be poured into gypsum, obtaining a positive copy, on which the work will be carried out. Digital scanning systems were not superior to conventional moldings when comparing fidelity, accuracy and detail reproduction; in contrast, they were superior to conventional impression when considering clinical chair time, patient and operator preference, and patient comfort.


RESUMEN: El objetivo de este estudio consistió en realizar una revisión bibliográfica sobre la precisión de los métodos de moldeo dental convencionales y digitales, así como presentar los diversos sistemas de escaneo intraoral tridimensionales. Se realizó una búsqueda bibliográfica en la base de datos de salud principal de PUBMED en la cual se recopilaron trabajos publicados entre 2008 y 2018. Se incluyeron estudios de laboratorio, informes de casos y revisiones sistemáticas, abordando temas que tratan con materiales digitales convencionales, moldeo y precisión. Se excluyeron los artículos que no evaluaron los materiales de moldeo, su comportamiento y técnicas para obtener una buena impresión de las estructuras orales. A través de una revisión exhaustiva en la literatura, obtuvimos los siguientes hallazgos: el paso más crítico en la preparación de una pieza protésica es la impresión de la preparación. La técnica convencional de moldeo consiste en obtener una copia negativa de la situación intraoral que se verterá en el yeso, obteniendo una copia positiva, sobre la cual se realizará el trabajo. Resulta que los sistemas de escaneo digital no fueron superiores a las molduras convencionales al comparar la fidelidad, precisión y reproducción de detalles; en cambio, fueron superiores a las molduras convencionales al considerar el tiempo de trabajo clínico, la preferencia del paciente y del operador y la comodidad del paciente.


Subject(s)
Humans , Dental Impression Technique/classification , Dental Impression Technique/instrumentation , Dental Impression Materials/chemistry , Dental Prosthesis Design , Printing, Three-Dimensional
3.
Rev. Fac. Odontol. Bauru ; 10(1): 35-41, jan.-mar. 2002. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-321830

ABSTRACT

O objetivo deste estudo foi o de avaliar o comportamento de moldes obtidos de diferentes técnicas de moldagem (por reembasamento sem e com alívio de lâmina plástica, e impressäo única simultânea), utilizando siliconas por adiçäo (SA), Express-3M e por condensaçäo (SC), 3M. Foi utilizado, como padräo, um troquel metálico simulando um preparo para coroa métalica. A partir deste foram obtidos, após a realizaçäo das diferentes técnicas de moldagem, troquéis de gesso (Durone-Dentsply). Nestes, foram feitos enceramentos de coroas com abertura oclusal e, em seguida, fundidos em liga de Cu-Al. No grupocontrole as fundiçöes foram obtidas diretamente do troquel padräo. O desajuste foi medido em funçäo dasdiscrepâncias das fundiçöes no troquel padräo, por meio de um microscópio de profundidade. Os resultados obtidos em m foram: Controle (fundiçäo obtida sem processo de moldagem)- 327,6; SC reembasamento sem alívio- 1734,1; SC reembasamento com alívio- 883,8; SC impressäo única- 598,6; SA reembasamento sem alívio- 571,6; SA reembasamento com alívio- 620,7; SA impressäo única- 648,6. Estas médias foram submetidas aos testes ANOVA e Tukey (p < 0,05). A técnica de impressäo única ou simultânea com silicona de reaçäo por condensaçäo promoveu resultados similares às técnicas com silicona por adiçäo. O processo de fundiçäo exerceu uma influência significativa na adaptaçäo das restauraçöes, sendo que a silicona por adiçäo sofreu menor influência face ao tipo de técnica de moldagem


Subject(s)
Dental Impression Materials , Dental Impression Technique/classification , Dental Casting Technique
4.
Rev. Fac. Odontol. Bauru ; 9(3/4): 167-172, jul.-dez. 2001. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-321822

ABSTRACT

Através da avaliaçäo de mensuraçöes horizontais em modelos de gesso tipo IV (Vel-mix) posicionadosnum perfilômetro, foram comparadas três técnicas de moldagens em implantes odontológicos. Na primeirafoi utilizado polissulfeto (Permlastic), moldeira individual e pinos cônicos (Nobelpharma), na segundapolissulfeto, moldeira individual e pinos quadrados (Nobelpharma), finalmente na terceira utilizou-sepolissulfeto, moldeira individual e pinos quadrados unidos com resina acrílica. Baseado na metodologiaempregada concluiu-se que näo houve alteraçöes estatisticamente significantes entre as três técnicas. Entretanto, as medidas de todos os modelos de gesso obtidos se apresentavam diferentes das do modeloOriginal


Subject(s)
Dental Impression Technique/classification , Dental Implants , Dental Prosthesis
6.
Rev. Fac. Odontol. Bauru ; 8(1/2): 23-9, jan.-jun. 2000. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-298437

ABSTRACT

Avaliou-se o reembasamento de moldes obtidos pela técnica de moldagem com resina acrílica gelada comparativamente à uma técnica convencional de moldagem com casquete preenchido com mercaptana. Foi utilizado um dispositivo metálico contendo um troquel para casquetes e um para moldagem. Os troquéis foram metalizados pela eletrodeposiçäo de íons prata no molde. A alteraçäo dimensional dos moldes foi mensurada em microscópio de profundidade, pela discrepância de alinhamento horizontal entre a borda oclusal de um anel de aço que simula uma coroa total e se adapta perfeitamente ao troquel padräo, e a face oclusal de cada troquel reproduzido. As médias das alteraçöes dimensionais e respectivos desvios-padräo, em micrômetros foram: A-) 678,8 (ñ59,2) para Duralay sem reembasamento, 379,9 (ñ72,9) para Duralay com reembasamento e 18,8 (ñ6,2) para o Permlastic. A resina acrílica sem reembasamento apresentou maior alteraçäo dimensional. Troquéis reproduzidos a partir dos moldes de mercaptana apresentaram-se dimensionalmente mais próximos do padräo. O reembasamento demonstrou proporcionar melhora significante na moldagem com a resina acrílica gelada


Subject(s)
In Vitro Techniques , Dental Impression Materials/chemistry , Dental Impression Technique/standards , Elastomers/classification , Elastomers/chemistry , Dental Materials/classification , Dental Materials/chemistry , Dental Impression Materials/classification , Models, Dental/classification , Models, Dental/standards , Acrylic Resins/classification , Acrylic Resins/chemistry , Dental Impression Technique/classification
8.
In. Ferreira, Flávio Vellini. Ortodontia: diagnóstico e planejamento clínico. Säo Paulo, Artes Médicas, 3 ed; 1999. p.141-57, ilus. (BR).
Monography in Portuguese | LILACS, BBO | ID: lil-271651
9.
In. Ferreira, Flávio Vellini. Ortodontia: diagnóstico e planejamento clínico. Säo Paulo, Artes Médicas, 3 ed; 1999. p.225-32, ilus, tab. (BR).
Monography in Portuguese | LILACS, BBO | ID: lil-271655
10.
Bauru; s.n; 1999. 162 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-255897

ABSTRACT

As restauraçöes fixas säo rotineiramente fabricadas sobre um modelo de gesso, obtidos a partir do molde de um dente preparado. A precisäo na adaptaçäo destas é influenciada diretamente pelas propriedades dos materiais de moldagem empregado. Qualquer que seja o elastômero eleito, o método mais confiável para se avaliar o seu desempenho em conduzir a modelos de gesso fiéis, parece ser aquele no qual é empregado uma coroa-padräo que se adapta com precisäo a um troquel apropriado. Este trabalho tem por objetivo avaliar se dentre as técnicas da dupla moldagem (com alívio de 1 e 2 mm) e a do casquete, existe uma mais adequada ou se ambas apresentam adequaçöes suficiente e semelhantes. Foram empregados cinco elastômeros (Express, Impregum F, Imprint, Permlastic e President), os moldes foram obtidos empregando-se um dispositivo de moldagem idealizado por ARAÚJO e JORGENSEN (6) e vazados com gesso especial tipo IV (Vel-Mix). A coroa-padräo foi posicionada nos troquéis e avaliada, quanto à sua precisäo de adaptaçäo, em um microscópio de mediçäo de profundidade. Os resultados mostraram que a técnica do casquete apresentou melhores resultados para os materiais Impregum F e Imprint, vindos a seguir o Express e o President (ambos com alívio de 2 mm) e o Express (alívio de 1 mm); o Permlastic e o Express, na técnica do casquete, apresentaram piores resultados que os anteriores, mas semelhnates entre si, sendo o President (casquete) semelhante à este último; o President (alívio de 1 mm), foi o que apresentou pior resultado


Subject(s)
Dental Impression Technique/classification , Dental Impression Technique/instrumentation , Crowns , Silicone Elastomers/chemistry , Dental Impression Materials/chemistry , Models, Anatomic
11.
Bauru; s.n; 1999. 104 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-256213

ABSTRACT

O sucesso clínico da prótese dentária é dependente em grande parte, da precisäo dimensional dos materiais e das técnicas de moldagens. A técnica do casquete individual de acrílico é um procedimento que possibilita excelentes resultados clínicos sendo extremamente precisa e previsível. Todavia, se estes casquetes se movimentarem durante a moldagem de transferência, que visa moldar as estruturas adjacentes e remover os casquetes da boca, o relacionamento interpilares será afetado e o modelo obtido näo reproduzirá fielmente o posicionamento tridimensional das estruturas moldadas. Utilizou-se um modelo-mestre em aço inoxidável, simulando uma prótese fixa com dois pilares intercalados por dois pônticos. Pontos de referência foram gravados nas superfícies oclusais e vestibulares dos pilares desse modelo-mestre permitindo que se obtivessem as medidas interpilares. O referido modelo-mestre foi usado para obtençäo de moldes através da técnica do casquete individual. Para a moldagem intracasquete usou-se um polissulfeto. Para realizar a moldagem de transferência, quatro diferentes materiais de moldagem foram empregados: alginato, silicona de condensaçäo, silicona de adiçäo e polissulfeto. Para os quatro tipos de materiais, testou-se a moldagem de transferência com casquetes isolados e com casquetes unidos com resina acrílica. Os resultados obtidos mostraram que, independente da técnica utilizada para moldagem de transferência, todos os modelos apresentaram distâncias interpilares aumentadas. As maiores alteraçöes nas distâncias interpilares ocorreram quando a moldagem de tranferência foi realizada com alginato. O procedimento de unir os casquetes com resina acrílica antes da moldagem de transferência reduziu a alteraçäo dimensional para todos os materiais testados. Entretanto, para o alginato e para a silicona de condensaçäo, essa reduçäo näo teve significado estatístico. Quando a moldagem de transferência foi executada com silicona de adiçäo ou polissulfeto, a alteraçäo dimensional interpilares foi sensivelmente reduzida e a uniäo dos casquetes com resina acrílica produziu modelos significantemente mais precisos


Subject(s)
Dental Impression Technique/classification , Dental Impression Technique/standards , Alginates/analysis , Denture, Partial, Fixed , Silicone Elastomers/analysis , Silicone Elastomers/classification , Dental Impression Materials/analysis
12.
14.
In. Ferreira, Flávio Vellini. Ortodontia: diagnóstico e planejamento clínico. Säo Paulo, Artes Médicas, 2 ed; 1998. p.143-57, ilus. (BR).
Monography in Portuguese | LILACS, BBO | ID: lil-271504
15.
In. Ferreira, Flávio Vellini. Ortodontia: diagnóstico e planejamento clínico. Säo Paulo, Artes Médicas, 2 ed; 1998. p.227-32, ilus, tab. (BR).
Monography in Portuguese | LILACS, BBO | ID: lil-271508
16.
In. Busato, Adair Luiz Stefanello; Barbosa, Alcebíades Nunes; Bueno, Márcia; Baldissera, Rudimar Antônio. Dentística: restauraçöes em dentes anteriores. Säo Paulo, Artes Médicas, 1997. p.417-41, ilus.
Monography in Portuguese | LILACS, BBO | ID: biblio-871921
17.
Asunción; EDIFAO; 1996. 46 p. ilus.
Monography in Spanish | LILACS, BDNPAR | ID: lil-321039
18.
In. Feller, Christa; Bottino, Marco Antonio. Atualizaçäo na clínica odontológica: a prática da clínica geral. s.l, Artes Médicas, 1994. p.281-93, ilus. (BR).
Monography in Portuguese | LILACS, BBO | ID: lil-187706
SELECTION OF CITATIONS
SEARCH DETAIL